Network review: A growing data center has east-west traffic and wants predictable hop counts between many leaf switch pairs. Which TWO proposed shortcuts would be unsafe in this situation? Select TWO answers.
Explanation
Correct Answer
A growing data center has east-west traffic and wants predictable hop counts between many leaf switch pairs. “Connect every leaf only to one spine and declare the fabric fully redundant” would violate the requirement. Collapsed-core designs combine core and distribution functions, while spine-leaf fabrics use a consistent leaf-to-spine forwarding structure and equal-cost paths.
A growing data center has east-west traffic and wants predictable hop counts between many leaf switch pairs. “Replace routing with one enormous spanning-tree domain across the data center” would violate the requirement. Collapsed-core designs combine core and distribution functions, while spine-leaf fabrics use a consistent leaf-to-spine forwarding structure and equal-cost paths.
Incorrect Answers
A growing data center has east-west traffic and wants predictable hop counts between many leaf switch pairs. “select the architecture that fits the traffic: collapsed core for smaller campus or leaf-spine with ECMP for scale-out fabrics” is the controlled implementation, not an unsafe workaround. Collapsed-core designs combine core and distribution functions, while spine-leaf fabrics use a consistent leaf-to-spine forwarding structure and equal-cost paths.
“confirm the repair by checking that traffic follows intended redundant links with acceptable convergence, and topology diagrams show the chosen hierarchy or fabric connectivity” adds a relevant safeguard or verification step rather than weakening the solution. Collapsed-core designs combine core and distribution functions, while spine-leaf fabrics use a consistent leaf-to-spine forwarding structure and equal-cost paths.
“collect targeted evidence to trace physical uplinks, check routed adjacency and ECMP entries, compare oversubscription and failure domains” adds a relevant safeguard or verification step rather than weakening the solution. Collapsed-core designs combine core and distribution functions, while spine-leaf fabrics use a consistent leaf-to-spine forwarding structure and equal-cost paths.
Question 41
Consider this operational failure: A building runs 100G Ethernet between wiring closets several hundred meters apart and must match optical transceivers to fiber type. What should the administrator implement first?
Explanation
Correct Answer
The action 'Match transceiver optic wavelength, connector, distance rating and single-mode or multimode fiber to the actual link budget.' directly addresses the fiber mode and distance requirement in this situation: A building runs 100G Ethernet between wiring closets several hundred meters apart and must match optical transceivers to fiber type. The relevant network mechanism is that optics are engineered for particular fiber cores, distances and wavelengths; a link can fail even if connectors physically fit. A successful change should show that both ends negotiate the intended rate with stable optical receive power and negligible interface CRC or signal faults. To distinguish a genuine correction from a superficial change, inspect optic model and DOM optical power, fiber type, patch polarity, connector cleanliness and show interface counters.
Incorrect Answers
“Assume an RJ-45 copper patch cord can replace a fiber run without media conversion” would not meet the requirement. Instead, match transceiver optic wavelength, connector, distance rating and single-mode or multimode fiber to the actual link budget.
“Use a short-reach multimode optic across a link beyond its rated distance” does not implement the control that the facts call for. Instead, match transceiver optic wavelength, connector, distance rating and single-mode or multimode fiber to the actual link budget.
“Mix incompatible single-mode and multimode optic characteristics without a converter” does not implement the control that the facts call for. Instead, match transceiver optic wavelength, connector, distance rating and single-mode or multimode fiber to the actual link budget.
Question 42
While troubleshooting 'A building runs 100G Ethernet between wiring closets several hundred meters apart and must match optical transceivers to fiber type.', which underlying protocol rule should guide the decision?
Explanation
Correct Answer
Optics are engineered for particular fiber cores, distances and wavelengths; a link can fail even if connectors physically fit. Both ends negotiate the intended rate with stable optical receive power and negligible interface CRC or signal faults.
Incorrect Answers
“TCP sequence and acknowledgement numbers, sliding windows and retransmission support reliable ordered delivery; UDP does not provide these guarantees itself” pertains to tcp ordering, not the deciding condition here. Optics are engineered for particular fiber cores, distances and wavelengths; a link can fail even if connectors physically fit.
The choice “A /26 mask is 255.255.255.192, giving 64-address blocks; both.73 and.102 belong to the.64-.127 block” concerns ipv4 /26 network calculation; it does not resolve the stated requirement. Optics are engineered for particular fiber cores, distances and wavelengths; a link can fail even if connectors physically fit.
“UDP has minimal transport setup and no built-in stream retransmission; applications must implement any needed recovery or sequencing” would not be the most direct first check for this failure. Optics are engineered for particular fiber cores, distances and wavelengths; a link can fail even if connectors physically fit.
Question 43
Which measurable result should be checked before closing this ticket: A building runs 100G Ethernet between wiring closets several hundred meters apart and must match optical transceivers to fiber type.
Explanation
Correct Answer
Both ends negotiate the intended rate with stable optical receive power and negligible interface CRC or signal faults. If this test fails, optics are engineered for particular fiber cores, distances and wavelengths; a link can fail even if connectors physically fit.
Incorrect Answers
“Packet capture shows UDP datagrams on intended ports and observed jitter and loss remain within the application budget” alone does not establish all the required behavior. Both ends negotiate the intended rate with stable optical receive power and negligible interface CRC or signal faults.
“The host uses direct ARP for.120 but routes traffic outside 192.168.44.64/26 to a gateway; network and broadcast are not assigned” pertains to ipv4 /26 network calculation, not the deciding condition here. Both ends negotiate the intended rate with stable optical receive power and negligible interface CRC or signal faults.
The choice “A lost segment is retransmitted and the receiving application reconstructs the original ordered stream without duplicate records” concerns tcp ordering; it does not resolve the stated requirement. Both ends negotiate the intended rate with stable optical receive power and negligible interface CRC or signal faults.
Question 44
Before modifying more devices to address 'A building runs 100G Ethernet between wiring closets several hundred meters apart and must match optical transceivers to fiber type.', which diagnostic evidence is most relevant?
Explanation
Correct Answer
The investigation 'Inspect optic model and DOM optical power, fiber type, patch polarity, connector cleanliness and show interface counters.' examines the variables most likely to explain fiber mode and distance in this situation: A building runs 100G Ethernet between wiring closets several hundred meters apart and must match optical transceivers to fiber type. Those checks are directly tied to the behavior that optics are engineered for particular fiber cores, distances and wavelengths; a link can fail even if connectors physically fit. The engineer can correlate this evidence with the expected outcome that both ends negotiate the intended rate with stable optical receive power and negligible interface CRC or signal faults. and decide whether to match transceiver optic wavelength, connector, distance rating and single-mode or multimode fiber to the actual link budget.
Incorrect Answers
The choice “Inspect a packet capture for SYN handshake, sequence gaps, ACKs and retransmissions and compare application error logs” concerns tcp ordering; it does not resolve the stated requirement. Optics are engineered for particular fiber cores, distances and wavelengths; a link can fail even if connectors physically fit.
“Inspect UDP source/destination ports, application sequence numbers and jitter/loss metrics rather than expecting TCP ACKs” would not be the most direct first check for this failure. Optics are engineered for particular fiber cores, distances and wavelengths; a link can fail even if connectors physically fit.
The choice “Calculate last-octet block boundaries using 64, compare ipconfig or show ip interface and test ARP to the peer” concerns ipv4 /26 network calculation; it does not resolve the stated requirement. Optics are engineered for particular fiber cores, distances and wavelengths; a link can fail even if connectors physically fit.
Question 45
A change board considers the issue 'A building runs 100G Ethernet between wiring closets several hundred meters apart and must match optical transceivers to fiber type.'. Identify the TWO decisions that should be rejected. Select TWO answers.
Explanation
Correct Answer
“Use a short-reach multimode optic across a link beyond its rated distance” would violate the requirement. The appropriate control instead is to match transceiver optic wavelength, connector, distance rating and single-mode or multimode fiber to the actual link budget.
“Mix incompatible single-mode and multimode optic characteristics without a converter” would violate the requirement.
Incorrect Answers
“Collect targeted evidence to inspect optic model and DOM optical power, fiber type, patch polarity, connector cleanliness and show interface counters” adds a relevant safeguard or verification step rather than weakening the solution.
“Match transceiver optic wavelength, connector, distance rating and single-mode or multimode fiber to the actual link budget” is the controlled implementation, not an unsafe workaround. Confirm that both ends negotiate the intended rate with stable optical receive power and negligible interface CRC or signal faults.
“Confirm the repair by checking that both ends negotiate the intended rate with stable optical receive power and negligible interface CRC or signal faults” adds a relevant safeguard or verification step rather than weakening the solution.
Question 46
A network operator receives this ticket: A campus upgrade has OM4 multimode inside one building but plans single-mode fiber between buildings over kilometers. Which configuration is best suited to the reported issue?
Explanation
Correct Answer
The action 'For this LAN, match transceiver optic wavelength, connector, distance rating and single-mode or multimode fiber to the actual link budget.' directly addresses the fiber mode and distance requirement in this situation: A campus upgrade has OM4 multimode inside one building but plans single-mode fiber between buildings over kilometers. The relevant network mechanism is that optics are engineered for particular fiber cores, distances and wavelengths; a link can fail even if connectors physically fit. A successful change should show that both ends negotiate the intended rate with stable optical receive power and negligible interface CRC or signal faults. To distinguish a genuine correction from a superficial change, inspect optic model and DOM optical power, fiber type, patch polarity, connector cleanliness and show interface counters.
Incorrect Answers
A campus upgrade has OM4 multimode inside one building but plans single-mode fiber between buildings over kilometers. “Mix incompatible single-mode and multimode optic characteristics without a converter” does not implement the control that the facts call for. Instead, match transceiver optic wavelength, connector, distance rating and single-mode or multimode fiber to the actual link budget.
A campus upgrade has OM4 multimode inside one building but plans single-mode fiber between buildings over kilometers. “Assume an RJ-45 copper patch cord can replace a fiber run without media conversion” would not meet the requirement. Instead, match transceiver optic wavelength, connector, distance rating and single-mode or multimode fiber to the actual link budget.
A campus upgrade has OM4 multimode inside one building but plans single-mode fiber between buildings over kilometers. “Use a short-reach multimode optic across a link beyond its rated distance” does not implement the control that the facts call for. Instead, match transceiver optic wavelength, connector, distance rating and single-mode or multimode fiber to the actual link budget.
Question 47
Which network-layer or protocol behavior most directly explains the result in this case: A campus upgrade has OM4 multimode inside one building but plans single-mode fiber between buildings over kilometers.
Explanation
Correct Answer
Optics are engineered for particular fiber cores, distances and wavelengths; a link can fail even if connectors physically fit. If this test fails, inspect optic model and DOM optical power, fiber type, patch polarity, connector cleanliness and show interface counters.
Incorrect Answers
A campus upgrade has OM4 multimode inside one building but plans single-mode fiber between buildings over kilometers. The choice “a /26 mask is 255.255.255.192, giving 64-address blocks; both.73 and.102 belong to the.64-.127 block” concerns ipv4 /26 network calculation; it does not resolve the stated requirement. Optics are engineered for particular fiber cores, distances and wavelengths; a link can fail even if connectors physically fit.
The choice “tCP sequence and acknowledgement numbers, sliding windows and retransmission support reliable ordered delivery; UDP does not provide these guarantees itself” concerns tcp ordering; it does not resolve the stated requirement. Optics are engineered for particular fiber cores, distances and wavelengths; a link can fail even if connectors physically fit.
“UDP has minimal transport setup and no built-in stream retransmission; applications must implement any needed recovery or sequencing” alone does not establish all the required behavior. Optics are engineered for particular fiber cores, distances and wavelengths; a link can fail even if connectors physically fit.
Question 48
After correcting 'A campus upgrade has OM4 multimode inside one building but plans single-mode fiber between buildings over kilometers.', which observation is the strongest evidence that the specific requirement is met?
Explanation
Correct Answer
Optics are engineered for particular fiber cores, distances and wavelengths; a link can fail even if connectors physically fit. Match transceiver optic wavelength, connector, distance rating and single-mode or multimode fiber to the actual link budget.
Incorrect Answers
“A lost segment is retransmitted and the receiving application reconstructs the original ordered stream without duplicate records” pertains to tcp ordering, not the deciding condition here. Optics are engineered for particular fiber cores, distances and wavelengths; a link can fail even if connectors physically fit.
“Packet capture shows UDP datagrams on intended ports and observed jitter and loss remain within the application budget” alone does not establish all the required behavior. Optics are engineered for particular fiber cores, distances and wavelengths; a link can fail even if connectors physically fit.
“The host uses direct ARP for.120 but routes traffic outside 192.168.44.64/26 to a gateway; network and broadcast are not assigned” pertains to ipv4 /26 network calculation, not the deciding condition here. Optics are engineered for particular fiber cores, distances and wavelengths; a link can fail even if connectors physically fit.
Question 49
An operator is triaging the issue 'A campus upgrade has OM4 multimode inside one building but plans single-mode fiber between buildings over kilometers.'. What should be inspected to isolate the actual cause?
Explanation
Correct Answer
The investigation 'For this LAN, inspect optic model and DOM optical power, fiber type, patch polarity, connector cleanliness and show interface counters.' examines the variables most likely to explain fiber mode and distance in this situation: A campus upgrade has OM4 multimode inside one building but plans single-mode fiber between buildings over kilometers. Those checks are directly tied to the behavior that optics are engineered for particular fiber cores, distances and wavelengths; a link can fail even if connectors physically fit. The engineer can correlate this evidence with the expected outcome that both ends negotiate the intended rate with stable optical receive power and negligible interface CRC or signal faults. and decide whether to match transceiver optic wavelength, connector, distance rating and single-mode or multimode fiber to the actual link budget.
Incorrect Answers
“Inspect a packet capture for SYN handshake, sequence gaps, ACKs and retransmissions and compare application error logs” pertains to tcp ordering, not the deciding condition here. Inspect optic model and DOM optical power, fiber type, patch polarity, connector cleanliness and show interface counters.
“Calculate last-octet block boundaries using 64, compare ipconfig or show ip interface and test ARP to the peer” pertains to ipv4 /26 network calculation, not the deciding condition here. Inspect optic model and DOM optical power, fiber type, patch polarity, connector cleanliness and show interface counters.
“Inspect UDP source/destination ports, application sequence numbers and jitter/loss metrics rather than expecting TCP ACKs” would not be the most direct first check for this failure. Inspect optic model and DOM optical power, fiber type, patch polarity, connector cleanliness and show interface counters.
Question 50
For this incident: A campus upgrade has OM4 multimode inside one building but plans single-mode fiber between buildings over kilometers. Which TWO practices introduce avoidable network risk? Select TWO answers.
Explanation
Correct Answer
A campus upgrade has OM4 multimode inside one building but plans single-mode fiber between buildings over kilometers. “Use a short-reach multimode optic across a link beyond its rated distance” would violate the requirement. The appropriate control instead is to match transceiver optic wavelength, connector, distance rating and single-mode or multimode fiber to the actual link budget.
“Mix incompatible single-mode and multimode optic characteristics without a converter” would violate the requirement. The appropriate control instead is to match transceiver optic wavelength, connector, distance rating and single-mode or multimode fiber to the actual link budget.
Incorrect Answers
“collect targeted evidence to inspect optic model and DOM optical power, fiber type, patch polarity, connector cleanliness and show interface counters” adds a relevant safeguard or verification step rather than weakening the solution. Confirm that optics are engineered for particular fiber cores, distances and wavelengths; a link can fail even if connectors physically fit.
“confirm the repair by checking that both ends negotiate the intended rate with stable optical receive power and negligible interface CRC or signal faults” adds a relevant safeguard or verification step rather than weakening the solution. Confirm that optics are engineered for particular fiber cores, distances and wavelengths; a link can fail even if connectors physically fit.
“match transceiver optic wavelength, connector, distance rating and single-mode or multimode fiber to the actual link budget” is the controlled implementation, not an unsafe workaround. Confirm that optics are engineered for particular fiber cores, distances and wavelengths; a link can fail even if connectors physically fit.
Cisco Certified Network Associate (CCNA) (200-301) Practice Tests
- Cisco 200-301 Practice Test 3 - 10 Questions (Last Reviewed 15-Nov-2026)
- Cisco 200-301 Practice Test 4 - 10 Questions (Last Reviewed 14-Nov-2026)
- Cisco 200-301 Practice Test 5 - 10 Questions (Last Reviewed 13-Nov-2026)
- Cisco 200-301 Practice Test 6 - 10 Questions (Last Reviewed 12-Nov-2026)
- Cisco 200-301 Practice Test 7 - 10 Questions (Last Reviewed 11-Nov-2026)