Pass Fortinet NSE5_FSW_AD-7.6 Exam in First Attempt Guaranteed!
Get 100% Latest Exam Questions, Accurate & Verified Answers!
30 Days Free Updates, Instant Download!
Fortinet NSE5_FSW_AD-7.6 Practice Test 48
Question 470
At a cloud-connected branch operations team, engineers report during a monitoring alert investigation that a switch interface shows correct negotiated link speed but high-priority application packets still experience loss under bursts. The change must preserve authorized service while resolving the observed fault. The decisive evidence is that queue drop counters rise in the affected service class despite low physical error counts. Which matched corrective step and acceptance test should be approved?
Explanation
Correct Answer
Inspect egress queue counters and class scheduling alongside link throughput. Verify that the class meets loss and latency targets under representative mixed load. Queue drop counters rise in the affected service class despite low physical error counts. A healthy physical link does not guarantee uncongested QoS queue service.
Incorrect Answers
Inspect egress queue counters and class scheduling alongside link throughput. The check examines whether the corrected uplink carries representative load without increasing errors. This check measures the corrected uplink carries representative load without increasing errors. Queue drop counters rise in the affected service class despite low physical error counts. The class meets loss and latency targets under representative mixed load.
Verify the stack's supported member links identity and FortiLink discovery path. The check examines whether all intended physical switch members appear with stable unique identities in the controller. Queue drop counters rise in the affected service class despite low physical error counts. Inspect egress queue counters and class scheduling alongside link throughput. Verify that the class meets loss and latency targets under representative mixed load.
Configure and verify an approved NTP source with consistent timezone presentation. The check examines whether the class meets loss and latency targets under representative mixed load. Configure and verify an approved NTP source with consistent timezone presentation does not address the stated fault. The necessary correction is inspect egress queue counters and class scheduling alongside link throughput because a healthy physical link does not guarantee uncongested QoS queue service.
Question 471
At an industrial branch infrastructure team, engineers report during a planned FortiSwitch commissioning visit that two stack members use overlapping or unexpected member identifiers after a field replacement. The change must preserve authorized service while resolving the observed fault. Which trace or operational record should be used to verify the cause?
Explanation
Correct Answer
The membership table reports a duplicate or missing expected stack member identifier. Two stack members use overlapping or unexpected member identifiers after a field replacement. The correction is to reconcile supported stack member identities and confirm physical cabling before enabling service.
Incorrect Answers
The stack member remains isolated while inventory identifies an unsupported port role. Two stack members use overlapping or unexpected member identifiers after a field replacement. The membership table reports a duplicate or missing expected stack member identifier.
The switch port VLAN membership shows the contractor VLAN while the workstation request requires the finance VLAN. Two stack members use overlapping or unexpected member identifiers after a field replacement. The membership table reports a duplicate or missing expected stack member identifier.
Aggregate throughput measurements exceed the currently provisioned uplink capacity. Two stack members use overlapping or unexpected member identifiers after a field replacement. The membership table reports a duplicate or missing expected stack member identifier.
Question 472
At a cloud-connected branch operations team, engineers report during a monitoring alert investigation that a core uplink remains administratively up but applications lose packets as bad Ethernet frames accumulate. The change must preserve authorized service while resolving the observed fault. What supported change should the administrator prioritize for this incident?
Explanation
Correct Answer
Inspect optical and physical error counters and repair the failing link component. Input CRC and frame error counters rise during loss periods despite link-up status. Error counters can reveal a physical fault hidden by an up interface state. Confirm the repair by checking that the corrected uplink carries representative load without increasing errors.
Incorrect Answers
Check current STP root priorities and restore the approved topology design. Input CRC and frame error counters rise during loss periods despite link-up status. Inspect optical and physical error counters and repair the failing link component.
Capture bridge protocol frames on the suspected access edge and apply approved protection. Input CRC and frame error counters rise during loss periods despite link-up status. Inspect optical and physical error counters and repair the failing link component. Error counters can reveal a physical fault hidden by an up interface state.
Calculate system and per-port PoE capacity and rebalance to supported power hardware. Input CRC and frame error counters rise during loss periods despite link-up status. Inspect optical and physical error counters and repair the failing link component.
Question 473
At a municipal services IT network office, engineers report during a routed and switched campus acceptance test that two departments share a switch but no Layer 3 VLAN interface provides their authorized inter-VLAN transit. The change must preserve authorized service while resolving the observed fault. After the proposed correction, which result demonstrates that this particular issue is resolved?
Explanation
Correct Answer
Approved inter-VLAN sessions traverse the intended gateway and prohibited ones are denied. Hosts can communicate within a VLAN but cannot reach the documented local gateway. Inter-VLAN routing requires correctly addressed Layer 3 interfaces and policy. The correction is to configure the intended routed VLAN interface and permitted access policy.
Incorrect Answers
The client receives normal authorized data access while managed-switch control connectivity remains stable. Hosts can communicate within a VLAN but cannot reach the documented local gateway. Approved inter-VLAN sessions traverse the intended gateway and prohibited ones are denied. Inter-VLAN routing requires correctly addressed Layer 3 interfaces and policy.
Authorized external destinations use the intended gateway without opening guest-to-internal access. That does not establish the necessary result for hosts can communicate within a VLAN but cannot reach the documented local gateway. In this case, inter-VLAN routing requires correctly addressed Layer 3 interfaces and policy. Use configure the intended routed VLAN interface and permitted access policy.
A new endpoint obtains the expected lease gateway and DNS without a rogue server. Hosts can communicate within a VLAN but cannot reach the documented local gateway. Approved inter-VLAN sessions traverse the intended gateway and prohibited ones are denied.
Question 474
At a managed-site FortiLink support team, engineers report during a controller health review that a packet trace on the upstream FortiGate shows multicast packets but the receiving FortiSwitch access port has stopped forwarding them. The change must preserve authorized service while resolving the observed fault. The decisive evidence is that upstream packets continue while receiver-side capture is empty after the IGMP aging interval. Which matched corrective step and acceptance test should be approved?
Explanation
Correct Answer
Capture on both sides of the relevant switch forwarding boundary and inspect group membership. Verify that intended group frames appear at subscribed receivers with no unrelated multicast flood. Upstream packets continue while receiver-side capture is empty after the IGMP aging interval. This matters because packet capture should bracket the point where forwarding behavior diverges.
Incorrect Answers
Reduce supported mirrored sources or use a capture path with sufficient capacity. The check examines whether intended group frames appear at subscribed receivers with no unrelated multicast flood. Reduce supported mirrored sources or use a capture path with sufficient capacity does not address the stated fault. The necessary correction is capture on both sides of the relevant switch forwarding boundary and inspect group membership.
Capture on both sides of the relevant switch forwarding boundary and inspect group membership. The check examines whether an authorized client completes the EAP exchange and receives the intended limited network role. This check measures an authorized client completes the EAP exchange and receives the intended limited network role. Upstream packets continue while receiver-side capture is empty after the IGMP aging interval. Intended group frames appear at subscribed receivers with no unrelated multicast flood.
Run a supported cable diagnostic and inspect physical interface errors before adjusting routes. The check examines whether the replaced cable negotiates correctly with stable counters and restored application traffic. Upstream packets continue while receiver-side capture is empty after the IGMP aging interval. Capture on both sides of the relevant switch forwarding boundary and inspect group membership. Verify that intended group frames appear at subscribed receivers with no unrelated multicast flood.
Question 475
At a multi-building campus switching team, engineers report during an access-layer service migration that a contractor adds redundant physical links between stacked switches without a supported loop prevention or aggregation plan. The change must preserve authorized service while resolving the observed fault. What underlying control or forwarding rule is most relevant to this failure?
Explanation
Correct Answer
Redundant cables require an explicit loop-free forwarding design. A contractor adds redundant physical links between stacked switches without a supported loop prevention or aggregation plan.
Incorrect Answers
Multichassis aggregation requires correctly formed peer and downstream relationships. A contractor adds redundant physical links between stacked switches without a supported loop prevention or aggregation plan. Redundant cables require an explicit loop-free forwarding design.
Physical signal degradation is visible through optical and frame-error measurements. A contractor adds redundant physical links between stacked switches without a supported loop prevention or aggregation plan. Redundant cables require an explicit loop-free forwarding design.
Supported stack topology and port capabilities are model dependent. That does not establish the necessary result for a contractor adds redundant physical links between stacked switches without a supported loop prevention or aggregation plan. In this case, redundant cables require an explicit loop-free forwarding design.
Question 476
At a university campus network group, engineers report during a distribution stack redesign that a FortiLink aggregate is configured for a topology different from the actual pair of downstream switches. The change must preserve authorized service while resolving the observed fault. What underlying control or forwarding rule is most relevant to this failure?
Explanation
Correct Answer
FortiLink split-interface design depends on actual switch connectivity. FortiLink aggregate configuration and switch connection diagram disagree on downstream peers.
Incorrect Answers
FortiLink scale limits depend on the controller platform and product version. That does not establish the necessary result for FortiLink aggregate configuration and switch connection diagram disagree on downstream peers. FortiLink split-interface design depends on actual switch connectivity.
Multi-tier FortiLink topologies require continuous supported intermediate management forwarding. FortiLink aggregate configuration and switch connection diagram disagree on downstream peers. FortiLink split-interface design depends on actual switch connectivity.
Discovery and administrator authorization are separate FortiLink onboarding stages. FortiLink aggregate configuration and switch connection diagram disagree on downstream peers. FortiLink split-interface design depends on actual switch connectivity.
Question 477
At a datacenter wired reliability group, engineers report during a network performance escalation that switches disappear from the FortiGate controller following a FortiOS upgrade that was not checked against their FortiSwitchOS versions. The change must preserve authorized service while resolving the observed fault. Which observed outcome proves the approved recovery was effective?
Explanation
Correct Answer
All intended managed switches reconnect and retain configurations after maintenance. Switches disappear from the FortiGate controller following a FortiOS upgrade that was not checked against their FortiSwitchOS versions. This matters because mixed Fortinet product releases must be checked for management-plane support.
Incorrect Answers
Management memory and active sessions stabilize without losing needed monitoring. Switches disappear from the FortiGate controller following a FortiOS upgrade that was not checked against their FortiSwitchOS versions. All intended managed switches reconnect and retain configurations after maintenance.
The device enrolls only with the intended FortiGate and receives current site settings. Switches disappear from the FortiGate controller following a FortiOS upgrade that was not checked against their FortiSwitchOS versions. All intended managed switches reconnect and retain configurations after maintenance. Mixed Fortinet product releases must be checked for management-plane support.
Management addresses are unique and switch-controller connectivity remains stable after reload. Switches disappear from the FortiGate controller following a FortiOS upgrade that was not checked against their FortiSwitchOS versions. All intended managed switches reconnect and retain configurations after maintenance. Mixed Fortinet product releases must be checked for management-plane support.
Question 478
At a campus network troubleshooting team, engineers report during an intermittent LAN outage that an NMS displays an online FortiSwitch chassis but cannot retrieve interface utilization because required permitted SNMP access is incomplete. The change must preserve authorized service while resolving the observed fault. Which finding most convincingly confirms the suspected failure mechanism?
Explanation
Correct Answer
Network polling reaches the device but interface OIDs return denied or unavailable results. An NMS displays an online FortiSwitch chassis but cannot retrieve interface utilization because required permitted SNMP access is incomplete.
Incorrect Answers
Receive power trends downward while TX values and negotiated speed remain steady. An NMS displays an online FortiSwitch chassis but cannot retrieve interface utilization because required permitted SNMP access is incomplete. Network polling reaches the device but interface OIDs return denied or unavailable results.
The mirror configuration identifies a different source port than the printer's learned MAC location. An NMS displays an online FortiSwitch chassis but cannot retrieve interface utilization because required permitted SNMP access is incomplete. Network polling reaches the device but interface OIDs return denied or unavailable results.
MAC movement logs show the identical source switching between two edge ports repeatedly. That does not establish the necessary result for an NMS displays an online FortiSwitch chassis but cannot retrieve interface utilization because required permitted SNMP access is incomplete. Network polling reaches the device but interface OIDs return denied or unavailable results.
Question 479
At a regional hospital network engineering group, engineers report during a controlled wiring-closet upgrade that FortiSwitch routing directs a service prefix toward a gateway that has no reachable interface in that routing context. The change must preserve authorized service while resolving the observed fault. The decisive evidence is that the route table has the configured destination but cannot resolve the stated next hop. Which matched corrective step and acceptance test should be approved?
Explanation
Correct Answer
Correct next-hop reachability and supported static route placement. Verify that the authorized service prefix resolves over the expected interface and succeeds end to end. The route table has the configured destination but cannot resolve the stated next hop. A configured route is only useful if its next hop is resolvable.
Incorrect Answers
Verify and apply the proper data versus tagged voice VLAN assignments for the combined endpoint port. The check examines whether the handset registers on the authorized voice subnet while the computer remains on its data VLAN. The route table has the configured destination but cannot resolve the stated next hop. Correct next-hop reachability and supported static route placement. Verify that the authorized service prefix resolves over the expected interface and succeeds end to end.
Configure the supported DHCP relay path on the routed gateway toward the approved server. The check examines whether the authorized service prefix resolves over the expected interface and succeeds end to end. Configure the supported DHCP relay path on the routed gateway toward the approved server does not address the stated fault. The necessary correction is correct next-hop reachability and supported static route placement.
Correct next-hop reachability and supported static route placement. This check concerns authorized external destinations use the intended gateway without opening guest-to-internal access, not the required outcome. The route table has the configured destination but cannot resolve the stated next hop. The authorized service prefix resolves over the expected interface and succeeds end to end.
Question 480
At a managed network service provider, engineers report during a controller migration that a field engineer changes a FortiLink-managed access port directly on the switch and the change disappears after reboot. The change must preserve authorized service while resolving the observed fault. Which trace or operational record should be used to verify the cause?
Explanation
Correct Answer
The local running state differs from FortiGate managed-switch configuration and is lost after reconciliation. A field engineer changes a FortiLink-managed access port directly on the switch and the change disappears after reboot. This matters because fortiGate is the authoritative configuration owner in FortiLink-managed mode. The correction is to modify the port through the authoritative FortiGate switch-controller policy instead.
Incorrect Answers
The upgrade plan omits model compatibility tests and rollback or service impact windows. A field engineer changes a FortiLink-managed access port directly on the switch and the change disappears after reboot. The local running state differs from FortiGate managed-switch configuration and is lost after reconciliation. FortiGate is the authoritative configuration owner in FortiLink-managed mode.
Per-tenant traffic counters show one group consuming most shared egress capacity. A field engineer changes a FortiLink-managed access port directly on the switch and the change disappears after reboot. The local running state differs from FortiGate managed-switch configuration and is lost after reconciliation. FortiGate is the authoritative configuration owner in FortiLink-managed mode.
Discovery reaches the controller but compatibility diagnostics reject the software pairing. That does not establish the necessary result for a field engineer changes a FortiLink-managed access port directly on the switch and the change disappears after reboot. In this case, fortiGate is the authoritative configuration owner in FortiLink-managed mode. Use modify the port through the authoritative FortiGate switch-controller policy instead.
Fortinet NSE 5 - FortiSwitch 7.6 Administrator (NSE5_FSW_AD-7.6) Practice Tests
- Fortinet NSE5_FSW_AD-7.6 Practice Test 46 - 10 Questions (Last Reviewed 12-Oct-2026)
- Fortinet NSE5_FSW_AD-7.6 Practice Test 47 - 10 Questions (Last Reviewed 11-Oct-2026)
- Fortinet NSE5_FSW_AD-7.6 Practice Test 48 - 10 Questions (Last Reviewed 10-Oct-2026)
- Fortinet NSE5_FSW_AD-7.6 Practice Test 49 - 10 Questions (Last Reviewed 09-Oct-2026)
- Fortinet NSE5_FSW_AD-7.6 Practice Test 50 - 10 Questions (Last Reviewed 08-Oct-2026)