Fortinet NSE5_FSW_AD-7.6 Practice Test 39

Question 380

At a regional security operations and campus network team, engineers report during a privileged access-policy review that a legacy printer uses MAC-based authentication and receives unrestricted employee network access with no device restrictions. The change must preserve authorized service while resolving the observed fault. Which observed outcome proves the approved recovery was effective?

  1. approved printers work on limited services while unknown MACs cannot access employee resources
  2. the accepted identity reaches only employee-approved services while guests remain isolated
  3. only authorized DNS queries cross the tenant boundary and other flows fail
  4. the replacement system gets access while unknown MACs remain denied

Explanation

Correct Answer

A:

Approved printers work on limited services while unknown MACs cannot access employee resources. An unknown MAC and an approved printer both receive the same broad authorization. Fallback authentication should preserve least privilege and device role separation.

Incorrect Answers

B:

The accepted identity reaches only employee-approved services while guests remain isolated. An unknown MAC and an approved printer both receive the same broad authorization. Approved printers work on limited services while unknown MACs cannot access employee resources. Fallback authentication should preserve least privilege and device role separation.

C:

Only authorized DNS queries cross the tenant boundary and other flows fail. An unknown MAC and an approved printer both receive the same broad authorization. Approved printers work on limited services while unknown MACs cannot access employee resources.

D:

The replacement system gets access while unknown MACs remain denied. That does not establish the necessary result for an unknown MAC and an approved printer both receive the same broad authorization. In this case, fallback authentication should preserve least privilege and device role separation. Approved printers work on limited services while unknown MACs cannot access employee resources.

Question 381

At an industrial branch infrastructure team, engineers report during a planned FortiSwitch commissioning visit that a replacement desk switch port was assigned to the contractor VLAN even though its approved endpoint belongs to the finance subnet. The change must preserve authorized service while resolving the observed fault. Which trace or operational record should be used to verify the cause?

  1. port VLAN settings show mismatched native or untagged identifiers across the same cable
  2. the peer VLAN membership lists voice service while the FortiSwitch uplink tagging table excludes it
  3. the switch port VLAN membership shows the contractor VLAN while the workstation request requires the finance VLAN
  4. the partner status lists one interface as up yet excluded from the selected aggregator

Explanation

Correct Answer

C:

The switch port VLAN membership shows the contractor VLAN while the workstation request requires the finance VLAN. A finance-subnet lease and cannot reach contractor-only resources.

Incorrect Answers

A:

Port VLAN settings show mismatched native or untagged identifiers across the same cable. A finance-subnet lease and cannot reach contractor-only resources. The switch port VLAN membership shows the contractor VLAN while the workstation request requires the finance VLAN.

B:

The peer VLAN membership lists voice service while the FortiSwitch uplink tagging table excludes it. That does not establish the necessary result for a finance-subnet lease and cannot reach contractor-only resources. The switch port VLAN membership shows the contractor VLAN while the workstation request requires the finance VLAN.

D:

The partner status lists one interface as up yet excluded from the selected aggregator. A finance-subnet lease and cannot reach contractor-only resources. The switch port VLAN membership shows the contractor VLAN while the workstation request requires the finance VLAN.

Question 382

At a datacenter wired reliability group, engineers report during a network performance escalation that a troubleshooter taps a single physical member of a balanced LAG and concludes that half the application flows are missing. The change must preserve authorized service while resolving the observed fault. Which trace or operational record should be used to verify the cause?

  1. upstream packets continue while receiver-side capture is empty after the IGMP aging interval
  2. the backup archive lacks switch-controller port policy present in the running environment
  3. the mirror configuration identifies a different source port than the printer's learned MAC location
  4. traffic counters show both LAG members active but capture observes only one member's hash-selected sessions

Explanation

Correct Answer

D:

Traffic counters show both LAG members active but capture observes only one member's hash-selected sessions. A troubleshooter taps a single physical member of a balanced LAG and concludes that half the application flows are missing.

Incorrect Answers

A:

Upstream packets continue while receiver-side capture is empty after the IGMP aging interval. A troubleshooter taps a single physical member of a balanced LAG and concludes that half the application flows are missing. Traffic counters show both LAG members active but capture observes only one member's hash-selected sessions.

B:

The backup archive lacks switch-controller port policy present in the running environment. A troubleshooter taps a single physical member of a balanced LAG and concludes that half the application flows are missing. Traffic counters show both LAG members active but capture observes only one member's hash-selected sessions.

C:

The mirror configuration identifies a different source port than the printer's learned MAC location. A troubleshooter taps a single physical member of a balanced LAG and concludes that half the application flows are missing. Traffic counters show both LAG members active but capture observes only one member's hash-selected sessions.

Question 383

At a manufacturing plant switching team, engineers report during a multi-tenant change audit that a delegated tenant maintenance window shuts the physical connection used by other tenants and the global FortiGate switch controller. The change must preserve authorized service while resolving the observed fault. After the proposed correction, which result demonstrates that this particular issue is resolved?

  1. tenant frames traverse only explicitly approved uplinks in segmented tests
  2. forbidden inter-tenant probes fail and business-authorized exceptions remain operational
  3. isolated tenant maintenance leaves shared switch control and other tenants operational
  4. each device is correctly authorized at its real site and receives only that site's VLANs

Explanation

Correct Answer

C:

Isolated tenant maintenance leaves shared switch control and other tenants operational. Controller heartbeats for unrelated tenants disappear when one tenant port is changed.

Incorrect Answers

A:

Tenant frames traverse only explicitly approved uplinks in segmented tests. Controller heartbeats for unrelated tenants disappear when one tenant port is changed. Isolated tenant maintenance leaves shared switch control and other tenants operational.

B:

Forbidden inter-tenant probes fail and business-authorized exceptions remain operational. Controller heartbeats for unrelated tenants disappear when one tenant port is changed. Isolated tenant maintenance leaves shared switch control and other tenants operational.

D:

Each device is correctly authorized at its real site and receives only that site's VLANs. Controller heartbeats for unrelated tenants disappear when one tenant port is changed. Isolated tenant maintenance leaves shared switch control and other tenants operational.

Question 384

At a university campus network group, engineers report during a distribution stack redesign that a shared FortiSwitch access interface is allocated to tenant B although its endpoint contract identifies tenant A. The change must preserve authorized service while resolving the observed fault. Which finding most convincingly confirms the suspected failure mechanism?

  1. controller port-to-VDOM mapping shows B while the client authorization matrix specifies A
  2. tenant A dashboard queries return devices assigned to tenant B
  3. FortiLink aggregate configuration and switch connection diagram disagree on downstream peers
  4. per-tenant traffic counters show one group consuming most shared egress capacity

Explanation

Correct Answer

A:

Controller port-to-VDOM mapping shows B while the client authorization matrix specifies A. A shared FortiSwitch access interface is allocated to tenant B although its endpoint contract identifies tenant A. This matters because multi-tenancy requires explicit port ownership and independent network access boundaries. The correction is to assign the switch port to the correct supported tenant or VDOM ownership scope.

Incorrect Answers

B:

Tenant A dashboard queries return devices assigned to tenant B. A shared FortiSwitch access interface is allocated to tenant B although its endpoint contract identifies tenant A. Controller port-to-VDOM mapping shows B while the client authorization matrix specifies A.

C:

FortiLink aggregate configuration and switch connection diagram disagree on downstream peers. A shared FortiSwitch access interface is allocated to tenant B although its endpoint contract identifies tenant A. Controller port-to-VDOM mapping shows B while the client authorization matrix specifies A. Multi-tenancy requires explicit port ownership and independent network access boundaries.

D:

Per-tenant traffic counters show one group consuming most shared egress capacity. A shared FortiSwitch access interface is allocated to tenant B although its endpoint contract identifies tenant A. Controller port-to-VDOM mapping shows B while the client authorization matrix specifies A. Multi-tenancy requires explicit port ownership and independent network access boundaries.

Question 385

At a retail chain voice-network operations unit, engineers report during an endpoint onboarding incident that an uplink pairs long-reach single-mode transceivers with an incompatible multimode fiber run. The change must preserve authorized service while resolving the observed fault. Which observed outcome proves the approved recovery was effective?

  1. the link maintains intended speed and error-free operation under sustained traffic
  2. optical receive levels and stable negotiated link meet module and reach specifications
  3. all intended links forward as one LAG with clean failover and no unintended loop
  4. a supported optic establishes stable link while telemetry reports normal conditions

Explanation

Correct Answer

B:

Optical receive levels and stable negotiated link meet module and reach specifications. Optical diagnostics show no usable receive signal with interfaces administratively enabled. Transceiver and fiber medium compatibility determines physical link feasibility. The correction is to choose approved optics and fiber matching wavelength media and reach for both ends.

Incorrect Answers

A:

The link maintains intended speed and error-free operation under sustained traffic. Optical diagnostics show no usable receive signal with interfaces administratively enabled. Optical receive levels and stable negotiated link meet module and reach specifications. Transceiver and fiber medium compatibility determines physical link feasibility.

C:

All intended links forward as one LAG with clean failover and no unintended loop. Optical diagnostics show no usable receive signal with interfaces administratively enabled. Optical receive levels and stable negotiated link meet module and reach specifications.

D:

A supported optic establishes stable link while telemetry reports normal conditions. That does not establish the necessary result for optical diagnostics show no usable receive signal with interfaces administratively enabled. In this case, transceiver and fiber medium compatibility determines physical link feasibility. Use choose approved optics and fiber matching wavelength media and reach for both ends.

Question 386

At a retail chain voice-network operations unit, engineers report during an endpoint onboarding incident that bulk transfers marked by workstations consume a priority queue intended for real-time calling. The change must preserve authorized service while resolving the observed fault. Which finding most convincingly confirms the suspected failure mechanism?

  1. client DHCP discover frames are visible locally but the remote server sees no relayed requests
  2. queue telemetry attributes much of the priority traffic to non-phone workstation MACs
  3. a phone LLDP neighbor record lacks the expected network-policy TLV even though the voice VLAN exists
  4. the handset attempts the advertised tag and switch counters show no membership for it

Explanation

Correct Answer

B:

Queue telemetry attributes much of the priority traffic to non-phone workstation MACs. Bulk transfers marked by workstations consume a priority queue intended for real-time calling. QoS marking cannot be trusted automatically from arbitrary user endpoints. The correction is to classify and remark at the trusted network edge before admitting frames to the priority queue.

Incorrect Answers

A:

Client DHCP discover frames are visible locally but the remote server sees no relayed requests. Bulk transfers marked by workstations consume a priority queue intended for real-time calling. Queue telemetry attributes much of the priority traffic to non-phone workstation MACs.

C:

A phone LLDP neighbor record lacks the expected network-policy TLV even though the voice VLAN exists. Bulk transfers marked by workstations consume a priority queue intended for real-time calling. Queue telemetry attributes much of the priority traffic to non-phone workstation MACs.

D:

The handset attempts the advertised tag and switch counters show no membership for it. Bulk transfers marked by workstations consume a priority queue intended for real-time calling. Queue telemetry attributes much of the priority traffic to non-phone workstation MACs. QoS marking cannot be trusted automatically from arbitrary user endpoints.

Question 387

At a regional hospital network engineering group, engineers report during a controlled wiring-closet upgrade that a copper endpoint negotiates unstable throughput after a technician forces an incompatible link speed policy. The change must preserve authorized service while resolving the observed fault. Which networking or FortiSwitch management principle explains the appropriate response?

  1. physical signal degradation is visible through optical and frame-error measurements
  2. physical Ethernet peers must agree on compatible signaling parameters
  3. transceiver and fiber medium compatibility determines physical link feasibility
  4. duplicate Layer 3 addresses create ambiguous neighbor resolution

Explanation

Correct Answer

B:

Physical Ethernet peers must agree on compatible signaling parameters. A copper endpoint negotiates unstable throughput after a technician forces an incompatible link speed policy.

Incorrect Answers

A:

Physical signal degradation is visible through optical and frame-error measurements. A copper endpoint negotiates unstable throughput after a technician forces an incompatible link speed policy. Physical Ethernet peers must agree on compatible signaling parameters.

C:

Transceiver and fiber medium compatibility determines physical link feasibility. A copper endpoint negotiates unstable throughput after a technician forces an incompatible link speed policy. Physical Ethernet peers must agree on compatible signaling parameters.

D:

Duplicate Layer 3 addresses create ambiguous neighbor resolution. A copper endpoint negotiates unstable throughput after a technician forces an incompatible link speed policy. Physical Ethernet peers must agree on compatible signaling parameters.

Question 388

At a municipal services IT network office, engineers report during a routed and switched campus acceptance test that a switch refresh orders an optic not listed for its target FortiSwitch hardware and firmware combination. The change must preserve authorized service while resolving the observed fault. The decisive evidence is that hardware compatibility records flag the installed module as unsupported or unrecognized. Which change and verification result together address the same root cause?

  1. consult current compatible transceiver guidance and validate the exact supported model — confirm: a supported optic establishes stable link while telemetry reports normal conditions
  2. check the model-specific stack deployment guide and move the connection to supported ports — confirm: the expected stack peers appear healthy and forwarding remains stable during a planned link test
  3. choose approved optics and fiber matching wavelength media and reach for both ends — confirm: a supported optic establishes stable link while telemetry reports normal conditions
  4. consult current compatible transceiver guidance and validate the exact supported model — confirm: the link maintains intended speed and error-free operation under sustained traffic

Explanation

Correct Answer

A:

Consult current compatible transceiver guidance and validate the exact supported model. Verify that a supported optic establishes stable link while telemetry reports normal conditions. Hardware compatibility records flag the installed module as unsupported or unrecognized. Module support must be checked against product model and software release.

Incorrect Answers

B:

Check the model-specific stack deployment guide and move the connection to supported ports. The check examines whether the expected stack peers appear healthy and forwarding remains stable during a planned link test. Hardware compatibility records flag the installed module as unsupported or unrecognized. Consult current compatible transceiver guidance and validate the exact supported model. Verify that a supported optic establishes stable link while telemetry reports normal conditions.

C:

Choose approved optics and fiber matching wavelength media and reach for both ends. The check examines whether a supported optic establishes stable link while telemetry reports normal conditions. Choose approved optics and fiber matching wavelength media and reach for both ends does not address the stated fault. The necessary correction is consult current compatible transceiver guidance and validate the exact supported model.

D:

Consult current compatible transceiver guidance and validate the exact supported model. The check examines whether the link maintains intended speed and error-free operation under sustained traffic. This check measures the link maintains intended speed and error-free operation under sustained traffic. Hardware compatibility records flag the installed module as unsupported or unrecognized. A supported optic establishes stable link while telemetry reports normal conditions.

Question 389

At a warehouse network protection team, engineers report during a switch-edge security assurance test that an IP phone authenticates but a connected laptop is admitted with the voice device's privileged profile. The change must preserve authorized service while resolving the observed fault. The decisive evidence is that RADIUS and port-session records show the computer inheriting the handset authorization. Which change and verification result together address the same root cause?

  1. configure supported separate phone and computer authentication and role assignment — confirm: phone registers and laptop receives only its own correct data permissions
  2. configure supported separate phone and computer authentication and role assignment — confirm: the accepted identity reaches only employee-approved services while guests remain isolated
  3. update the authorized IP-to-port identity binding before permitting traffic — confirm: the readdressed host communicates while forged source addresses remain blocked
  4. tighten user and device role matching so the guest policy applies only to guests — confirm: phone registers and laptop receives only its own correct data permissions

Explanation

Correct Answer

A:

Configure supported separate phone and computer authentication and role assignment. Verify that phone registers and laptop receives only its own correct data permissions. RADIUS and port-session records show the computer inheriting the handset authorization. Multi-device edge authentication must maintain independent endpoint identities.

Incorrect Answers

B:

Configure supported separate phone and computer authentication and role assignment. The check examines whether the accepted identity reaches only employee-approved services while guests remain isolated. This check measures the accepted identity reaches only employee-approved services while guests remain isolated. RADIUS and port-session records show the computer inheriting the handset authorization. Phone registers and laptop receives only its own correct data permissions.

C:

Update the authorized IP-to-port identity binding before permitting traffic. The check examines whether the readdressed host communicates while forged source addresses remain blocked. RADIUS and port-session records show the computer inheriting the handset authorization. Configure supported separate phone and computer authentication and role assignment. Verify that phone registers and laptop receives only its own correct data permissions.

D:

Tighten user and device role matching so the guest policy applies only to guests. The check examines whether phone registers and laptop receives only its own correct data permissions. Tighten user and device role matching so the guest policy applies only to guests does not address the stated fault. The necessary correction is configure supported separate phone and computer authentication and role assignment because multi-device edge authentication must maintain independent endpoint identities.

Question 390

At a datacenter wired reliability group, engineers report during a network performance escalation that a link still forwards frames but DOM receive power approaches a documented lower warning threshold. The change must preserve authorized service while resolving the observed fault. What acceptance evidence should close this incident without exposing another network segment?

  1. the MAC remains on its approved interface and affected clients retain connectivity
  2. receive power stays in the supported range with low error rates across the service window
  3. FortiLink connectivity works on the controlled path with employee VLAN isolation intact
  4. the replaced cable negotiates correctly with stable counters and restored application traffic

Explanation

Correct Answer

B:

Receive power stays in the supported range with low error rates across the service window. Receive power trends downward while TX values and negotiated speed remain steady. This matters because optical receive telemetry provides early warning of signal-path degradation.

Incorrect Answers

A:

The MAC remains on its approved interface and affected clients retain connectivity. Receive power trends downward while TX values and negotiated speed remain steady. Receive power stays in the supported range with low error rates across the service window. Optical receive telemetry provides early warning of signal-path degradation.

C:

FortiLink connectivity works on the controlled path with employee VLAN isolation intact. Receive power trends downward while TX values and negotiated speed remain steady. Receive power stays in the supported range with low error rates across the service window.

D:

The replaced cable negotiates correctly with stable counters and restored application traffic. That does not establish the necessary result for receive power trends downward while TX values and negotiated speed remain steady. In this case, optical receive telemetry provides early warning of signal-path degradation. Receive power stays in the supported range with low error rates across the service window.

Fortinet NSE 5 - FortiSwitch 7.6 Administrator (NSE5_FSW_AD-7.6) Practice Tests